Your source code contains an EXEC CICS statement before the PROCEDURE DIVISION header was found.
               	
            
            	
            	
            
               		
               			
               - System Action:
 
               			
               - The EXEC statement is treated as comments, a SEVERE error is raised, and processing continues with the word following the
                  END-EXEC.
               
 
               		
               		
               			
               - Resolution:
 
               			
               - Correct the placement of the EXEC CICS statement within the source program.
 
               		
               		
               			
               - Module:
 
               			
               - cicsprep (dfhxc2pp)
 
               		
               		
               			
               - Destination:
 
               			
               - Source Listing, .TRL file, STDOUT