Use the Rumba TN3270 emulator to run the MFDEMO application on the IMSDEMO 
		enterprise server region. 
	 
 
   
 
	 With the IMSDEMO 
		enterprise server region started in 
		Enterprise Server (see the 
		Start IMSDEMO section in the previous topic), you can now run the MFDEMO application from the Rumba TN3270 mainframe display, and add data to the IMS database. 
	 
 
	 The installation of 
		Enterprise Developer includes the 
		Micro Focus Rumba emulator. The Rumba TN3270 Mainframe Display is embedded within 
		Enterprise Developer. As part of this tutorial, you use the embedded Rumba display to run the application. 
	 
 
	 Configure the TN3270 settings in 
		  Enterprise Developer
 
		 
		Here, you check your 
		  Enterprise Developer options and ensure that the embedded Rumba display is selected: 
		
 
		 
		  - In the IDE, click 
			 Window > Preferences. 
		  
- Expand 
			 Micro Focus > Enterprise Server, and click 
			 TN3270. 
		  
- Ensure that 
			 Enable display, 
			 Rumba (Embedded) and 
			 Connect automatically are all selected. 
		  
- Click 
			 OK. 
		  
Start the 
		  Rumba Mainframe Display View
 
		 
		
 
	 Start the MFDEMO Application
 
		 
		Note: Before interacting with the Rumba display, be sure that 
		  
Enterprise Server Administration is not open in an 
		  
Enterprise Developer tab. 
		
 
 
		 
		  -  On the IMS sign-on screen, type 
			 SYSAD into both the 
			 USERID and 
			 PASSWORD fields using the 
			 Tab key to move from one to the other; then press 
			 Enter. 
		  
- Press 
			 Ctrl+Shift+Z to clear the 
			 Rumba Mainframe Display screen. 
		  
- Enter 
			 MFDEMO 
			  with a trailing space. 
			 Rumba shows the MFDEMO initial menu screen, DEMO91. 
			  
Add Data
 
		 
		In the sections that follow, each set of instructions includes a screen shot showing the terminal emulator with required fields in green and red. 
		
 
		Tip: To navigate between fields on a terminal emulator screen, press 
		  
Tab to move to the next field, and 
		  
Shift+Tab to move to the previous field. 
		
 
 
		 
		   
			 - Create a TESTDEPT table 
			 
-  
				 
				  - In the 
					 FUNCTION CODE field, type 
					 A to select the <A>DD function. 
					 This action advances your cursor to the 
						TABLE-ID field. 
					  
- In the 
					 TABLE-ID field, type 
					 TESTDEPT.
  
 
- Press 
					 Enter. 
					 This action advances you to the DEMO92 input screen. 
					  
 
- Input records 
			 
-  
				 
				  - Complete the following fields as indicated: 
					 
 
						   
							  
								| DESCRIPTION | A TABLE OF TEST DEPARTMENTS |   
								| NUMBER OF CHARACTERS IN ELEMENT KEY | 20 |   
								| NUMBER OF CHARACTERS IN ELEMENT | 50 |   
								| PASSWORD PROTECT | N |  
 
- Tab to the first entry field under 
					 ELEMENT KEY; then add the following records: 
					 
 
							  
								| ELEMENT KEY | ELEMENT VALUE/DESCRIPTION |   
								| 123 | DEPARTMENT 123 |   
								| 234 | DEPARTMENT 234 |  
 
- Tab to the 
					 RETURN field; then type 
					 X.
  
 
- Press 
					 Enter to return to the main menu. 
				  
 
- Add an additional record 
			 
-  
				 
				  - In the 
					 FUNCTION CODE field, type 
					 C to select the <C>HANGE function. 
					 This action advances your cursor to the 
						TABLE-ID field. 
					  
- In the 
					 TABLE-ID field, type 
					 TESTDEPT.
  
 
- Press 
					 Enter. 
					 This action advances you to the DEMO92 input screen. 
					  
- Tab to the first field in the third row under 
					 FUNC; then add the following record: 
					 
 
							  
								| FUNC | ELEMENT KEY | ELEMENT VALUE/DESCRIPTION |   
								| A | 345 | DEPARTMENT 345 |  
 
- Tab to the 
					 RETURN field; then type 
					 X.
  
 
- Press 
					 Enter to return to the main menu. 
				  
 
- Add the TESTERS table and records 
			 
-  
				 
				  - Using the same methods as you did to create the TESTDEPT table and add records, add the TESTERS table using these values: 
					 
 
						   
							  
								| DESCRIPTION | A TABLE OF TESTERS |   
								| NUMBER OF CHARACTERS IN ELEMENT KEY | 20 |   
								| NUMBER OF CHARACTERS IN ELEMENT | 50 |   
								| PASSWORD PROTECT | N |  
 
- Then add the following records: 
					 
 
							  
								| ELEMENT KEY | ELEMENT VALUE/DESCRIPTION |   
								| JOHN SMITH | IMS DC TEST TECHNICIAN |   
								| JANE JONES | IMS DB TEST TECHNICIAN |  
 
  
 
- Press 
					 Enter to return to the main menu. 
				  
 
- Exit MFDEMO 
			 
-  
				 
				  - On the main menu, type 
					 E into the 
					 FUNCTION CODE field; then press 
					 Enter. 
					 This action takes you to the TRANCODE - MFDEMO - ENDED screen. 
					  
  
 
- Disconnect from the TN3270 display. To do this in Rumba, click 
					 Disconnect on the toolbar 
					  . .